Critical Varnish Reduced in Two Turbo Compressors

CJC reduced critical varnish and particle contamination in two turbo compressor lubrications systems, cleaning the existing oil without complete oil replacement.

Case study written by: Cille Steffensen Suhr

Application Snapshot

Industry:

Industry

Oil type:

Mineral turbine oil,

ISO VG 46

Executive Summary

Two identical turbo compressors, each with approximately 400 L of turbine oil, showed elevated particle contamination and varnish levels, including a critical MPC of 42.3 on one unit. This increased the risk of varnish deposits, oxidation, and wear.


To restore the existing oil rather than replace the complete oil charge, CJC Varnish Removal Units (VRU) were connected sequentially to the two lubrications systems. Following filtration, MPC varnish contamination was reduced by approximately 84% and 94%, while particles larger than 4 μm were reduced by more than 91% and 99% after one pass.


The oil was cleaned without requiring complete oil replacement, and independent laboratory analysis concluded that the oil was suitable for continued use.

Critical varnish reduced by up to 94%

Approximately 84% and 94% reduction in MPC varnish contamination.

Complete oil replacement avoided

Oil was cleaned resulting in no requirement in a complete oil replacement.

Particles reduced by more than 91% and 99%

More than 91% and 99% reduction in particles >4 μm after one pass.

Oil suitable for continued use

Following the filtration the oil analysis showed no apparent abnormality.

Turbo Compressor 1 oil analysis results before CJC filtration, after one pass and after one month.
Turbo Compressor 2 oil analysis results before and after CJC filtration.

Treatment and oil analysis

Unit 1:

  • Ran for 723 hours (30 days), filtering 32,535 L (81.3x turnover of the oil volume).
  • MPC dropped from 42.3 → 2.5 after just a single pass, and was 2.4 after 1 month.
  • ISO 4406 improved from 22/16/10 → 13/12/9 (single pass) → 14/12/10 (1 month).


Unit 2:

  • Ran for 788 hours (33 days), filtering 35,460 L (88.7x turnover).
  • MPC dropped from 15.1 → 2.6 after 1 month.
  • ISO 4406 improved from 20/18/14 → 14/12/9.


An independent laboratory concluded after filtration: "results in order, no anomalies" / oil "suitable for continued use."

Customer Benefits Summary

  • Financial: Avoided replacing about 800 L of oil across two systems and the associated downtime and disposal costs. The oil was returned to service condition while the compressors stayed in operation.


  • Operational: Varnish and particle levels were brought to normal ranges, reducing the risk of valve sticking and control instability. The result was verified by independent laboratory analysis.


  • Environmental: Extended oil life means less waste oil and less new oil produced and transported.
Before-and-after turbine oil samples showing improved oil condition following CJC filtration.